Laboratory Infrared Heating Furnace

Shop the highest quality Laboratory Infrared Heating Furnace at our factory. Designed for efficiency and accuracy. Enjoy fast shipping and exceptional service.

Request a Quote
  • Laboratory Infrared Heating Furnace
  • Laboratory Infrared Heating Furnace
  • Laboratory Infrared Heating Furnace
  • Laboratory Infrared Heating Furnace

PRODUCTS DETAILS

  • Product Description

Laboratory Infrared Heating Furnace

一、Uses

The infrared heating furnace produced by our company is the latest generation of products in the world and is the best substitute for closed electric furnace. Applicable to industrial, agricultural, colleges and universities, industrial and mining enterprises, medical and health, research institutes and households for heating equipment.

二、Product features1, Laboratory Infrared Heating Furnace High efficiency infrared heating technology of environmental protection, heat quickly, heat by radiation is passed, thermal inertia small, the halogen-light, without any harm to human body, the heat performance is good, compared to common electric furnace thermal efficiency can be increased by 30%, long service life, (more than 5000 hours) is not affected by environment, compared with the ordinary electric furnace - electric stove wire exposed to high temperature oxidation in air, liquid splashes down easily burned electric stove wire, USES the international most advanced original heating and under microcrystalline glass protection, low failure rate.2, Adopting the latest high performance material microcrystal glass as the heating panel, the glass surface can withstand high temperature 900 degrees, vertically transfer infrared heat, the horizontal heat transfer is slow, the surface of microcrystal glass can rapidly heat up to 500 degrees, the sudden cold water will not crack.3, Microcomputer control heating process, digital display heating power adjustable, used to control the temperature of heating medium, heating time can be set arbitrarily according to the need.。4, The new electronic control technology - sensitive touch chips, to replace the traditional switch, fingers touch the glass panel is the control signal can be transmitted to the microcomputer controller, components without mechanical action, greatly reduces the equipment failure rate, at the same time because of micro crystal plate corrosion resistant properties, completely eliminate the possibility of corrosion control buttons, even strongly corrosive chemicals on the surface, also won't cause damage to instrument.5, A variety of composite protection technologies are adopted. As the heater is in a high-temperature working environment, it inevitably causes damage to the electronic circuit control part. For this reason, an auxiliary cooling fan is designed for the heater to protect the electronic components from working in a high-temperature environment.At the same time, we also designed the limit over-temperature protection function, that is, when the temperature exceeds the set limit value, the instrument will automatically stop heating, and when the temperature returns to normal, the instrument will automatically resume heating.6, The planar closed heating panel is suitable for a variety of heating methods and appliances, without open fire and without leakage of electricity. It can place the heated object directly on the heating panel without any worries of corrosion and pollution. This instrument is the upgrade of laboratory heating instruments. 三、Technical data:1、 Heating power:100-1000W adjustable,heating surface temperature:500℃2、 Heating area:Φ 150mm 3、 Timing range:0—9999 Minutes4、 Panel size:210mmx250mm四、 Instructions for use: AfterInfrared Heating Furnace is plugged in, the panel shall have the red power signal, according to a finger touch switch button area, heater start immediately, can touch and subtract the healthy modified heating power, you can according to need to change the heating power, need timing function, can touch key, regularly lit up regularly, you can touch and subtract the healthy modify the setting time, after use, fingers touch switch button area can be turned off. After the shutdown the wind motor runs for a period of time this is normal. Note: When do not adjust the delay, generally 30 minutes delay, when using according to about time to set the time.

Infrared furnace

infrared heating furnace

infrared furnace for laboratory

contact information

Hot Products

Twin Shaft Concrete Mixer

Twin Shaft Concrete Mixer

Cement Fineness Sieve Negative Pressure

Cement Fineness Sieve Negative Pressure

Laboratory Pulverizer

Laboratory Pulverizer

Laboratory Sample Grinder Machine Vibrating Sample Pulverizer Machine

Laboratory Sample Grinder Machine Vibrating Sample Pulverizer Machine

Stainless Steel Cement Le Chatelier Boiling Box/Cement Water Bath

Stainless Steel Cement Le Chatelier Boiling Box/Cement Water Bath

Cement Concrete Curing Box For Laboratoy

Cement Concrete Curing Box For Laboratoy

Concrete Air Content Meter (Air Entrainment Meter)

Concrete Air Content Meter (Air Entrainment Meter)

YH-40B Constant Temperature Humidity Standard Concrete Curing Chamber

YH-40B Constant Temperature Humidity Standard Concrete Curing Chamber

Laboratory Constant Temperature Incubators with Digital Controller

Laboratory Constant Temperature Incubators with Digital Controller

Laboratory Chemical Equipment 450 Degree Digital Heating Mantle

Laboratory Chemical Equipment 450 Degree Digital Heating Mantle

Contact us

Please feel free to give your inquiry in the form below We will reply you in 24 hours